01

Decision table

If you have not chosen between an enclosed chamber and a head-out cryosauna, start with the whole-body chamber guide.

Decision table
Buying considerationElectric systemNitrogen system
Recurring cooling inputElectricityLiquid nitrogen plus electricity
User positionEnclosed/head-in and head-out electric designs existOpen-top/head-out and enclosed nitrogen designs exist
Site focusPower, refrigeration layout, heat rejectionSupply access, storage, ventilation, monitoring and exhaust
Cost sensitivityUtility demand, maintenance and refrigeration serviceDelivered gas price, evaporation, tank rental and delivery schedule
Session capacityModel-specificModel-specific
Main failure in comparisonsIgnoring contractor and service costUsing gas price without delivery, rental or losses

Once the site comparison leaves a cooling option open, check the machines themselves: the electric chamber guide covers power and refrigeration layouts; the nitrogen cryosauna guide covers formats, tank choices and supply readiness. Confirm site fit before choosing by running cost.

Understand the bill / worked examples

What a daily running-cost claim leaves out

Electricity is power multiplied by time. A nitrogen bill depends on purchased liquid and supply charges. These two examples show the arithmetic separately; they do not compare equivalent treatments or establish a lower ownership cost.

01 / Electricity

Two power modes, one eight-hour day

41.0 kWh / example day

Cooling: 16.4 kWhHolding: 24.6 kWh

2 hours x 8.2 kW + 6 hours x 4.1 kW = 41.0 kWh. Artica publishes these mode ratings on its Element page, checked October 15, 2026. The hours are our illustration, not measured usage.

At 14.53 cents/kWh, the illustrative electricity amount is $5.96 a day, or $154.89 for 26 operating days. That rate is the EIA US commercial average for July 2026, released September 24; it is average revenue per kWh, not your energy-only tariff. Do not add a separate demand charge to that average to reconstruct a utility bill.

Room cooling and closed-day use are outside this operating-day illustration. To price your own bill, use a full day of measured consumption and the actual tariff schedule, including only separately charged fixed, demand or time-of-use items.

02 / Liquid nitrogen

The session liquid is only part of the bill

1,498 L / example month

  1. Sessions1,300 L10 paid sessions x 26 days x 5 L
  2. Other daily use78 L3 L x 26 operating days
  3. Storage / other losses120 L4 L x all 30 calendar days

At an assumed USD 2/L, plus USD 120 rental and USD 150 delivery fees, this example totals $3,266.00 for the month, or $12.56 per paid session. See the full liquid-nitrogen breakdown.

All quantities, the gas rate and fees here are example assumptions. The 5 L/session choice falls within a supplier's published pressurized range; it is not a measurement. Nitrogen-unit electricity, labor and other business costs are excluded. No purchase minimum or opening/closing inventory is modeled.

See published prices and the conditions behind them.

Worked examples with stated assumptions, not supplier offers or measurements of an operating site. These examples are not prefilled into your worksheets.

Where each technology fits

02

Electric equipment needs a site that can meet its published power, mechanical equipment and heat-rejection requirements. For nitrogen, confirm that local delivery, storage and room arrangements can meet the proposed model's requirements.

Have the supplier and the relevant local contractor check the same layout before ruling out a cooling option. An unanswered question calls for a document or site assessment.

03

Check six site constraints before choosing

Check six site constraints before choosing
Site constraintDocument to collectWhat it can tell youNext step
Electrical serviceCurrent model requirements: voltage, phase, frequency and circuit details; an assessment of the available site serviceWhich configurations can use the service and which would need an upgrade. Nitrogen equipment can also need electricityAsk the supplier and qualified local electrician to review the same configuration and drawing
Refrigeration placement and heatMechanical layout, component clearance, heat-rejection requirements and any wall or roof penetrationsWhether the proposed mechanical equipment fits; electric systems use different layoutsReview the layout with the supplier, landlord and relevant contractor before accepting a proposal
Gas delivery and storageLocal supply proposal, proposed vessel details and model-specific room requirementsWhether a nitrogen configuration has a workable supply and storage arrangement. An electric candidate can remain open while this is checkedName who supplies, installs, maintains and approves each part of the proposed arrangement
Staffed hours and workloadA documented operating cycle covering preparation, exposure, cleaning and recovery; operator requirements and downtime assumptionsWhether either candidate can deliver the proposed work during your staffed hoursUse the same paid and unpaid workload in the comparison below; check cycle time and staffing separately
Space and delivery accessFull operating layout, service clearances, weights and a delivery-route surveyWhether a specific configuration can be delivered, installed and serviced. A machine footprint alone can't answer thisList work still to be priced in the installation responsibility matrix
Local serviceWritten coverage for the proposed location, technician arrangements, parts support, response terms and exclusionsAvailable support, response times and costsRequest the missing terms and price the disruption case separately from normal operation

These are screening questions, not installation specifications. The Artica Vortex product page and CRYONiQ room-requirements guide show why you need documents for the exact configuration. Confirm local approval separately.

Use the installation responsibility checklist to agree who provides the documents and completes the work, including what must be ready before the next step can start.

Screen the two candidates
  1. Choose the format
  2. Check each site constraint
  3. Price the unresolved work

Estimate electricity from published figures

Use a rating-based illustration before you have measurements. The Artica examples assume 2 cooling hours and 6 holding hours. Everest uses its supplier's calculator day, whose operating hours are not specified.

The worked examples below are available without JavaScript.

Worked examples at 14.53 cents per kWh
EquipmentPublished input and chosen hoursIllustrative energyBenchmark costSource
Artica Element8.2 kW x 2 h + 4.1 kW x 6 h41 kWh$5.96Manufacturer mode ratings, checked October 15, 2026
Artica Vortex8.2 kW x 2 h + 4.1 kW x 6 h41 kWh$5.96Manufacturer mode ratings, checked October 15, 2026
CryoBuilt Everest90 kWh calculator day90 kWh$13.08Supplier calculator, checked October 15, 2026

Electricity benchmark: EIA US commercial average for July 2026, released September 24, 2026, checked October 15, 2026. It measures historical average revenue per kWh, not your energy-only tariff. Do not add separate demand fees to this benchmark to reconstruct a local bill.

Rated power and calculator assumptions are not measured use. Additional cooling, overnight and closed-day loads may be missing. These buttons show a separate estimate; they do not fill or replace your measured worksheet inputs.

Obtain matched cash quotes before comparing a purchase premium

A current electric-versus-nitrogen purchase-price gap is not established here. The earlier XC Plus catalog cash amount is a historical reference, while the current US catalog shows monthly advertising and quote requests. A monthly payment cannot supply the missing cash price or financing total.

Get dated cash quotations for the exact configurations, inclusions and destination. Keep delivery, site work, service and the measured operating workload comparable before calculating a purchase premium or offset period. Read the historical catalog references. The electricity examples above remain separate illustrations and do not establish a current purchase-price gap.

Cooling source and user geometry are separate choices

04

"Electric" and "nitrogen" describe how the cold is made. Whether the user's head is inside or outside the cold zone is a different question, and every combination exists:

  • The CRYO Science lineup includes the nitrogen-cooled, enclosed Arctic alongside its electric systems, so an enclosed chamber is not automatically electric.
  • The Vacuactivus Antarctica Electric page, checked October 6, 2026, describes electric cooling with the user's head outside the cold zone.

This matters for costs and operations. Gas consumption from a head-out cryosauna can't be transferred to a gas-cooled heat-exchange chamber. For each candidate, check the cooled body region, breathing environment, capacity, operator requirements and current instructions. Cooling technology alone doesn't tell you staffing, intended use or safety controls.

Set up a fair comparison

05

Pick one electric and one nitrogen model that can serve the same customer volume and service format. Then hold everything else equal: analysis period, operating days, completed sessions, finance treatment, labor rate and downtime.

Use one workload for both. For example, 10 completed sessions a day over 25 operating days gives 250 sessions a month for each candidate. Dividing one system's daily cost by 20 sessions and the other's by 10 manufactures a technology "advantage" that is really a volume difference.

Draw the same cost boundary. Electric energy should cover the documented system: chamber, mechanical unit, pull-down, runtime, standby and any share of room cooling. Nitrogen should cover model-specific use per session, separate precooling and losses, tank rental, minimum purchases and delivery terms. Note which costs continue in a month with no sessions; at zero sessions, cost per session is undefined.

Count cash once. For a cash purchase, count acquisition and site preparation once, then operating costs. For a financed purchase, count the actual upfront cash, fees, installments and any final payment - not the full purchase price as well. Don't add a bundled item a second time.

Use figures you can verify. Use capacity and temperature claims only when the maker states the measurement method. Base demand on your location, not the maker's revenue examples.

Stress both. Run a lower-demand case and a disruption case: a refrigeration outage for electric, a missed delivery for nitrogen.

Price local supply with the nitrogen inputs and the installed project with the common ownership worksheet.

06

Compare the same documented operating period

Read each electricity figure in its own units

Power in W or kW and energy in kWh answer different questions. These figures describe different operating states. A daily energy estimate also needs the operating schedule.

Published power labels and supplier calculator assumptions
ModelPublished figure and sourceHow to read it
CryoBuilt EverestCalculator input, not measured daily use. The operating schedule and whole-system boundary still need confirmation.
Artica ElementMode power ratings. An energy estimate also needs time in each mode and any additional loads.
Artica VortexMode power ratings. An energy estimate also needs time in each mode and any additional loads.
CRYONiQ CRYO XCSession figures conflict. Confirm the applicable rating for the offered electrical configuration. Neither label is measured energy.
CRYONiQ CRYO XC PlusSession figures conflict. Confirm the applicable rating for the offered electrical configuration. Neither label is measured energy.
Zimmer MedizinSystems Cryo 6Maximum therapy-power label. Not an all-mode maximum, energy per appointment or a circuit requirement.
Zimmer MedizinSystems Cryo 7Maximum input-power label, not measured energy per appointment or a circuit requirement.

For an operating budget, obtain measurements over a documented schedule and a consistent system boundary. For standby energy, ask for a correctly labeled power value.

First define one delivered cycle for both configurations. Then enter the same operating days, closed days, paid and unpaid workload, currency and tariff. Operating plus closed days must cover the whole calendar period you select.

Keep people and cycles distinct. The same number of cycles can involve different numbers of users and different staffing needs. Check capacity and operating requirements for each model separately.

Include full-day or overnight energy and closed-day liquid losses. Enter zero only when the measurement or supply terms support it. Whole-day electricity already includes the measured workload inside its system boundary, so don't add a separate cycle measurement on top of it.

Minimum circuit ampacity and connected load help plan the installation; neither is a measured kWh figure. Ask for measured energy use for a named configuration and period, with the equipment included in the measurement listed. Nitrogen use likewise needs a defined cycle, with precooling, storage and other losses listed separately.

The nitrogen system has its own electricity line in addition to purchased liquid and period fees. Add only costs that are priced separately. For labor, space, service, capital and other costs, say what the total includes and what is still missing. Name the line that covers any bundled cost so you count it once.

Label a multi-year total by what it includes

07

A five-year view needs delivered equipment cost, site work, finance outflow, completed sessions, local tariff, delivered nitrogen cost, tank fees, scheduled service, repair reserve, labor, downtime and end-of-term value, run at low, base and high utilization. The worksheet above covers one operating period. Replacement, price changes, the financing schedule and end value belong in the business-plan cash worksheet.

Name any total for what it covers. Electricity or gas plus planned maintenance and training can be correct arithmetic and still leave out rent, staff, marketing, finance and downtime. Keep an exclusions column next to it.

Also be careful with ranges. Two category-level low/high figures don't give you a ratio for your site. Compare at the same sessions, days, tariff basis and system boundary, and change those inputs openly in the downside case.

Questions before selection

08
  • Which site work is included in each delivered proposal?
  • What local service or gas coverage is available in writing?
  • How many completed sessions are realistic during the buyer's staffed hours?
  • Which costs continue during a low-volume month?
  • What event would stop operation and how quickly can it be resolved?
  • What contract obligations remain if the location closes or the equipment is replaced?

Make your choice

09

Keep each figure with its source and check date, and distinguish a written quote from an estimate. Choose the technology that fits the site and your cost scenarios. Write down why you rejected the other option so you can revisit the decision if a price or site condition changes.

If only one configuration fits the site and has local support, price its complete installation before comparing it with a cheaper alternative that still needs confirmation. If both fit, use the matched operating-period worksheet and compare the same costs. Wait for any deciding document or cost, and agree who will supply it.

Check the purchase and setup comparison before committing funds. Lower utility bills may come with higher installation costs.

For a monthly business budget, check how utility totals and delivered workload fit the ROI model. The worksheets use different periods and input definitions; amounts do not transfer automatically.

Assign the work around self-service

10

A self-service feature does not answer who prepares the room, responds to a problem or maintains the equipment. Before reducing a staffing allowance, obtain the applicable instructions for the offered mode and assign the work they require. Keep a supplier's automation claim separate from your approved operating plan.

Assign the work around self-service
Responsibility to clarifyWritten answer needed
Opening and equipment preparationApplicable tasks, responsible role and confirmation of readiness
User access and instructionsWho provides the required preparation and assistance
Supervision and interruptionWhat the specific mode requires and who responds
Cleaning and changeoverAssigned work, supplies and actual turnaround
Planned care and diagnosticsOperator tasks versus qualified service-provider work
Loss of power, network or remote supportApplicable instructions and the responsible escalation route
Closing and next-day readinessNamed role and questions still to answer

Use the demonstration checklist to time staff work alongside equipment runtime. Keep completed, test, unpaid and interrupted activity separate. For recurring care, use the maintenance notes; an advertised exposure duration alone cannot price the full workday.

Estimate electricity mode by mode

Running costs / Your measurements

Estimate electricity use mode by mode

Enter warm-up, completed cycles, ready time and room cooling separately. Unpaid cycles count toward consumption. Leave unmeasured amounts blank to see the blocks you can already calculate. A complete set of inputs gives an operating-day subtotal plus your entered period charges; closed-day loads are outside it.

Add documents and context for your file

Note the model, the documents you used and what each amount covers. Anything left blank stays unknown. The notes stay on this page and are included when you download or print.

Keep electricity bills, gas bills, equipment costs and the full business budget separate. Don't enter customer or personal information.

Enter non-overlapping measured energy blocks for one typical operating day: warm-up, active cycles and idle time must not include each other, and room cooling counts only if those measurements leave it out. A connection rating, amperage, peak kW or wind-chill figure can't fill an energy field. Enter zero only when it is confirmed. Every number starts blank, and nothing is sent or saved automatically.

Save measurements while waiting for missing readings. Blank fields stay unknown. This inputs-only CSV cannot restore the form.

Enter the measurements you have and calculate to see the known blocks. Blank amounts stay unknown.
Electricity formula and measurement limits

Daily kWh = warm-up kWh + (paid + unpaid completed cycles) x cycle kWh + idle hours x measured average idle kW + additional cooling kWh. Period energy = daily kWh x operating days. Entered subtotal = operating-day energy x tariff + other period electricity charges. Subtotal allocated per paid cycle = entered subtotal / (paid cycles/day x operating days); undefined at zero paid cycles.

This repeats one entered operating day across the billing period. It does not model variable schedules, overlapping loads, peak-demand timing, utility tariff tiers, taxes unless entered, non-operating days or unrecorded overnight loads. For the billing boundary and separately entered charges, read the commercial power-bill check. For a complete metered daily figure, use that figure in your own worksheet rather than adding the same energy again as component blocks. Acquisition, nitrogen, labor, rent, maintenance, revenue and profit are outside this calculator.

Calculation and CSV downloads need JavaScript. Open Electricity formula and measurement limits above for the manual calculation and its scope.

Compare your operating period

One calendar / Your documented inputs

Compare electric and nitrogen costs on the same workload

Both systems share one set of operating and closed days, paid and unpaid cycles, currency and electricity tariff. Remember that nitrogen equipment uses electricity too. Nothing is prefilled: no model costs, prices or demand.

Add documents and context for your file

Note the model, the documents you used and what each amount covers. Anything left blank stays unknown. The notes stay on this page and are included when you download or print.

Keep electricity bills, gas bills, equipment costs and the full business budget separate. Don't enter customer or personal information.

Shared calendar and rate

Electric system
Nitrogen system
Add other costs and say what each one covers

Amounts here cover the whole period. A separate amount is added to the utility subtotal. If a cost is already included elsewhere, name that line; if it is excluded, give the reason. While any category is unknown or excluded, no difference in selected costs is shown. Even five complete categories don't prove that every business cost is covered.

Electric selected period costs

Staff and direct labor

Rent and allocated space costs

Service, maintenance and downtime allowance

Equipment cash payments and finance

Other selected business costs

Nitrogen selected period costs

Staff and direct labor

Rent and allocated space costs

Service, maintenance and downtime allowance

Equipment cash payments and finance

Other selected business costs

Use measured full-day and overnight electricity that already includes the stated workload and cooling, and don't add the same load twice. Enter closed-day electricity and liquid losses separately. A breaker or connection rating is not a substitute. If a time-of-use or tiered tariff can't be expressed as one documented equivalent rate, work out that bill separately before comparing. Other daily nitrogen use stays outside the per-cycle amount. Enter zero only when it is confirmed. Nothing is sent or saved automatically.

Save incomplete inputs while waiting for measurements or quotes. Blank fields stay unknown; this CSV cannot restore the form.

No comparison is shown until all utility inputs and the cycle definition are entered.
Formula and comparison limits

Paid period cycles = paid/day x operating days. All period cycles = (paid + unpaid)/day x operating days. Electric utility cost = (operating-day kWh x operating days + closed-day kWh x closed days) x tariff + period electricity charges. Required nitrogen = ((paid + unpaid)/operating day x liters/cycle + other liters/operating day) x operating days + liters/closed day x closed days. Purchased liquid is the greater of required liquid and the stated period minimum. Nitrogen electricity includes its operating and closed days. Nitrogen utility cost = its electricity + purchased liquid x delivered price + other period charges. Selected separate costs add once; explicitly included costs do not add twice. Per-paid-cycle allocation uses all entered costs divided by paid cycles; it is undefined at zero paid cycles and is not a marginal treatment cost. This compares the costs you enter. It cannot confirm equivalent services, safe installation or delivery dates, and it does not forecast investment returns or future prices.

The interactive comparison needs JavaScript. The common-period definitions and formulas remain available for your own worksheet.

Plot cumulative purchase and running budgets

Your assumptions / monthly cash costs

When could the higher purchase price be recovered?

Enter two upfront totals and two comparable monthly cost budgets. Include the same workload and cost categories in each monthly budget, and keep purchase payments out of recurring costs so they are not counted twice.

No cost curve is shown before both monthly and upfront amounts are entered.

The interactive chart needs JavaScript. At month m, cumulative cash cost = upfront amount + m x monthly cost. No inflation, discounting, resale or revenue is modeled.

Sources