01

Check the Arctic version in your quote

The Arctic page on cryo.com lists these alternative supplies. The page does not say whether it describes the same revision as the earlier Arctic Performance figures below, so confirm which one is quoted.

Electrical alternatives listed for Arctic
One listed option
230 V50 Hz
The other listed option
110 V60 Hz

Ask which option your quote supplies and obtain its circuit requirements. Do not transfer the earlier 13 A peak label to the 110 V option.

Check the Arctic version in your quote
Purchase checkWhat the Arctic page listsWhat still needs an answer
Nitrogen useAbout 12 L per session, described as an averageDoes that include precooling, re-cooling and other liquid use?
Delivery weight549 kg with shipping crates; 305 kg without themWhich weight and package dimensions apply to each delivery stage?
Depth with door1000 mm / 41 inThose labels do not match. Request one dimensioned drawing before planning the room.

The older room minimums are not the new page's body dimensions. Match the product name and revision before using either set for your site.

02

Earlier Arctic Performance specifications

Earlier Arctic Performance specifications
SpecWhat the maker saysCheckedWhat to ask
Arctic coolingNitrogen heat exchangeOctober 6, 2026Do not apply the electric e-Arctic connection sheet.
Arctic formatAdjustable window; WBC and PBC modesOctober 6, 2026Confirm the intended configuration and operating instructions.
Minimum supply voltage220 VOctober 11, 2026Current delivered phase/frequency still need a drawing.
Maximum supply voltage230 VOctober 11, 2026Not a utility-consumption figure.
Peak current13 A peak, as stated by the makerOctober 11, 2026Not average operating current.
Minimum room length2.7 mOctober 11, 2026Not chamber-body length.
Minimum room width2.4 mOctober 11, 2026Not an approved site layout.
Minimum room height2.6 mOctober 11, 2026Check access and service space too.
Minimum door width90 cmOctober 11, 2026Check the actual delivery route.
03

Our take

Start by naming the exact model in every supplier question. A name that differs by one letter can change the utility and installation questions. Use the earlier Arctic Performance requirements only after matching the offered revision. Ask for a complete liquid-use estimate and the electrical drawing for that same unit.

For an electric shortlist, request the e-Arctic or Glacier configuration sheet rather than recycling the Arctic page. A remote machinery or water component has a different space boundary from the main chamber.

04

e-Arctic temperature labels

The e-Arctic product page gives different lower temperature endpoints:

What each part of the product page says
Technical Specification / Temperature
-80 to -90 C-112 to -130 F
Special features / Rapid Cooling Time / Air temperature
-80 to -110 C-112 to -166 F
Benefits / perceived value
-110 C-166 F

Fahrenheit values are converted from the published Celsius figures.

Checked October 19, 2026. Benefits also labels the first range as air temperature. The page does not explain the difference. The perceived value is not an air reading or a measurement we made. Ask for the quoted revision's air range, measurement conditions and definition of perceived temperature.

05

Ask for the complete electric layout

Ask for the complete electric layout
Electric-model questione-Arctic PerformanceGlacier Performance
Published US-frequency option208 V / 60 Hz / 60 A as stated by the maker208 V / 60 Hz; the page says a US voltage booster is required
Main chamber module, L x W x H1800 x 1000 x 2300 mm2100 x 1230 x 2500 mm
Other hardware to placeSeparate machinerySeparate machinery and water-cooling module
Layout issue to resolveOperating: 2310 x 2240 mm; approximate installation: 2008 x 1740 mm. Compare all three space labels before planning the roomSupplier describes water-cooling installation as outdoors. Compare three operating spaces.
Energy useCurrent rating is not measured kWh30 kW is a supplier power rating, not kWh per day

Use the figures above to screen your options, then ask for the electrical sheet and installation drawing for the exact unit offered. Confirm the complete component layout and US supply version before planning the room.

Request a drawing that identifies chamber, machinery and any water equipment, the working and installation spaces around each, connection routes and outdoor requirements if applicable. Then check voltage, frequency, phase and service scope against that same drawing. The installation guide explains the responsibility handoff.

Glacier: three operating spaces

Supplier space labels, not equipment-body dimensions.

01 / Chamber

Length x width
2,544 x 2,713 mm
Height
2,700 mm

02 / Machinery

Length x width
2,075 x 850 mm
Height
1,673 mm

03 / Water cooling

Length x width
2,300 x 1,110 mm
Height
1,110 mm

One scale, original L/W order; heights listed separately. These plots do not form a room plan.

Nine dimension labels checked ; manufacturer source. The water-cooling installation is described as outdoors.

Compare the three e-Arctic space labels
e-Arctic chamber: three published space labels

The operating rectangle is larger than the supplier's approximate installation rectangle. Ask which spaces apply to the quoted configuration before planning the room.

01 / Module space

Length x width
1,800 x 1,000 mm
Module-space height
2,300 mm

02 / Operating space

Length x width
2,310 x 2,240 mm

03 / Approximate installation space

Length x width
2,008 x 1,740 mm

All three plan rectangles use the same scale and original L/W order. Height is listed separately. The outlines do not assign clearances to particular sides or combine these labels into a room.

Dimension fields checked ; supplier dimension labels. The separate machinery, connections and service access still need the configured installation drawing.

06

Compare on the same basis

The electric/nitrogen cost comparison, full equipment price index and manufacturer document directory cover different next steps. For another electric document set, read MECOTEC; for nitrogen supply, use the local nitrogen worksheet.

Sources