Price and freight to confirm
See the whole-body equipment selection criteria for the wider shortlist.
| Item | What the maker says | What to ask |
|---|---|---|
| Equipment price on the product page | USD 75,998 | Configuration, tax, upgrades and complete site cost |
| Freight line, contiguous US | USD 2,500 | Whether charged separately or included in the quoted purchase amount |
| Other-area freight block | USD 3,500 | Applicable destinations and actual delivered scope |
| Shipping footnote | Contiguous US shipping described as included; other destinations require a custom quote | This conflicts with the separate freight block |
| Monthly financing teaser | A monthly payment is advertised | Lender, term, deposit, final payment and total payable require actual financing terms |
These are statements from different blocks of one supplier page, not three offers you can choose between. Ask Artica to identify the governing amount and attach the freight inclusions to the quote. Ask whether delivery includes unloading, inside placement, rigging, storage, return freight or restoration of the building.
Once Artica confirms the freight charge, compare the delivered amounts in the two-quote comparison. Add excluded contractor work to the installed budget alongside the supplier quote.
Electrical options and current labels
| Element option | Supply | Current | MCA |
|---|---|---|---|
| 60 Hz | Single phase, 208-240 V | 40 A | 26 A |
| 50 Hz | Single phase, 208-240 V | 50 A | 32 A |
The detailed values were checked on October 11, 2026. The menu options were checked October 14, 2026: 1 Phase, 208-240V, 50Hz; 1 Phase, 208-240V, 60Hz. A menu choice does not prove a delivered unit can switch between these versions.
A separate marketing block refers to 34 RLA and broad commercial-socket compatibility. That wording doesn't explain how it relates to the detailed current and MCA rows. Give your electrician the exact selected unit's current installation sheet and circuit requirements. Ask which current and MCA figures apply to your unit and any ancillary equipment. Your electrician needs that answer before selecting a breaker, cable or receptacle.
Amps and MCA are not measured energy consumption. To estimate daily kWh from the page's cooling and standby kW figures, you also need time in each mode, actual conditions and extra room cooling. Use a documented operating schedule and applicable utility tariff in the electricity cost worksheet.
The chamber and the space around it
| Dimension | What the maker says | What to ask |
|---|---|---|
| Unit width x depth x height | 76 x 36 x 90 inches | The unit envelope is not the room or transport envelope |
| Stated working width x depth x height | 105 x 71 x 95 inches | Supplier working-space claim, not an approved layout |
| Door swing | 30 inches | Check its actual path against access and surrounding equipment |
| Weight | 1200 lb | Not a floor-loading, lifting or delivery-path assessment |
These dimensions were checked on October 11, 2026. Artica states that Element does not need an external condenser. The installation block also imposes room airflow, ambient temperature, humidity and room-cooling conditions. Having no outdoor condenser does not remove those conditions.
Request a drawing for the delivered revision. Mark the operating and service spaces, full door movement, access route and any proposed connections. Have the responsible local contractors assess the room conditions and building work. For an optional heat-recovery connection, confirm the actual package, water and drainage scope separately. Do not infer those works from the base chamber price.
Use the installation responsibility register to distinguish the equipment supplier, buyer, landlord, electrician, HVAC contractor and local authority. Agree what each party will deliver and who will check completion.
What self-installation leaves to resolve
The supplier describes Element as designed for self-installation. For a commercial purchase, first ask what that term includes and excludes. It may describe the equipment package without settling delivery handling, electrical work, room cooling, permissions, commissioning or training.
| Stage | Documents to request |
|---|---|
| Before ordering | Exact model revision, selected supply, current installation documents and site assumptions |
| Before dispatch | Complete packing and delivery scope, access requirements, exclusions and agreed dates |
| Before accepting completion | Responsible party's completed commissioning or handover report, applicable training and open work |
| During ownership | Current operating instructions, care schedule, service contact and contract coverage |
Do not treat automated controls or a claim that staff are unnecessary as permission for unattended operation. Confirm the applicable instructions, operator responsibilities and local requirements for the exact use. The delivery and handover checklist helps you ask for completion documents and resolve open work; follow the supplier's instructions for operation.
Expansion and ownership costs
Artica promotes scalable cooling. Ask what an expansion proposal would change for your exact unit: compatibility and revision, hardware, power, heat rejection, space, downtime, commissioning and warranty. Get the future capacity and complete upgrade price in a separate proposal, using the expansion checklist to organize the questions.
The advertised warranty and service language also needs a contract. Identify which components, labor, travel and freight are covered, when the term starts, required maintenance and the process for service in your location. Remote monitoring is not the same deliverable as staffed support or an agreed site attendance time. Add recurring charges and uncovered costs to the service budget.
Your Element order and site checklist
Before ordering, get answers on delivery, electrical supply and site work using the checklist below. Keep the document title, revision and date with each answer, and leave missing answers unknown. Nothing in this worksheet is sent to Artica or saved automatically.
Open your checklist notes
Where Element fits
Keep Element on your shortlist when its exact configuration, room conditions and complete package can be documented for your site. Its public purchase reference helps start a budget, but it does not settle freight, site work, throughput or local service.
For a different Artica installation layout, read the Vortex buying guide. To compare suppliers, use the whole-body model shortlist and electric chamber guide. Choose on the room, workload and local service as well as purchase price.
Sources
- Element product page - Artica SystemsArtica Systems
- Artica cryotherapy chamber rangeArtica Systems